QSC SRA 3622 Bedienungsanleitung Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
19
SETUP- Low Frequency Filter
Channel 1’s low frequency filter is operated by
switches 2 and 3. Channel 2’s filter is operated
by switches 8 and 9.
FILTER ON: To turn the filter on, slide the switch to the right (Sw.2: Ch.1, Sw.9: Ch.2).
FILTER OFF: To turn the filter off, slide the appropriate switch to the left.
20 HERTZ: To set the filter for a 20 Hz. rolloff, slide the switch to the right (Sw.3: Ch.1, Sw.8: Ch.2).
50 HERTZ: To set the filter for a 50 Hz. rolloff, slide the appropriate switch to the left.
Unless you already have filtering in the signal path
preceding the amplifier, use the low frequency filter to
protect your speakers from cone overexcursion caused
by frequencies below the speaker’s limits. The speaker’s
documentation will specify the low frequency limit.
Generally, match the frequency selection to your
speaker’s low frequency capability. This improves
speaker performance by limiting subaudio cone move-
ment, making more power available for the speaker’s
rated frequency range.
Each channel has its own low frequency filter. Channel
1’s low frequency filter is operated by switches 2 and 3.
Channel 2’s filter is operated by switches 8 and 9.
Low Frequency Filters
NOTE! The filter on/off switch must be set to the “on” position for the frequency
selection to be active. If the on/off switch is set to the “off” position, no filtering will
take place regardless of the frequency selection.
SRA Series amplifier low
frequency response curves.
Output (dB)
Frequency (Hertz)
Filter= Off
Filter= 20 Hz.
Filter= 50 Hz.
Seitenansicht 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 39 40

Kommentare zu diesen Handbüchern